Linkdata 65P CC test

DIY500AMP interactive report | CC Sweep | Report date: 2026-06-07
Intended cutoff: 2.50 V | Normalized cutoff: 3.00 V | Selected tests: 5
Website export

Key Findings

Data Validation Notes

Summary Table

Test Name File Current Label Start Voltage (V) Minimum Voltage in File (V) End Voltage (V) Last Loaded Voltage (V) Average Test Current (A) Peak Power (W) Average Power (W) Capacity (mAh) Electricity (Wh) Runtime Runtime (s) LAB Room Temp (°C) Maximum Temperature (°C) Temperature Rise (°C) Average Voltage (V) Usable Capacity above 3.00V (mAh) Usable Energy above 3.00V (Wh) Capacity Below 3.00V (mAh) Usable Percent (%) Stop/Fairness Note Normalized Metric Note Data Quality Notes
Linkdata 65P 30A CC Linkdata_65P_30A_CC_IT8516P_CC_30A_CONT_SENSEON_TEMP_2026-06-06_23-11-42.csv 30A CC 4.2129 2.4933 2.4933 2.4933 29.9810 120.208 99.923 6511.930 21.70267 13:02 782.131 25.84 77.77 51.93 3.3328 5068.913 17.66737 1443.017 77.84 Reached or nearly reached the intended 2.50V cutoff. Crossed 3.00V. Usable metrics were interpolated at the cutoff. Repaired 8 voltage samples using power/current because the raw voltage was outside a realistic cell range.
Linkdata 65P 35A CC Linkdata_65P_35A_CC_IT8516P_CC_35A_CONT_SENSEON_TEMP_2026-06-06_20-23-23.csv 35A CC 4.2087 2.8329 2.8329 2.8329 34.9832 139.452 118.848 5695.001 19.34896 9:46 586.253 25.06 80.03 54.97 3.3975 5016.814 17.37006 678.187 88.09 Likely temperature-limited before 2.50V cutoff. Crossed 3.00V. Usable metrics were interpolated at the cutoff. Repaired 6 voltage samples using power/current because the raw voltage was outside a realistic cell range.
Linkdata 65P 40A CC Linkdata_65P_40A_CC_IT8516P_CC_40A_CONT_SENSEON_TEMP_2026-06-06_17-32-09.csv 40A CC 4.2132 3.1111 3.1111 3.1111 39.9753 157.718 139.412 4482.119 15.63156 6:44 403.634 25.35 80.08 54.73 3.4875 4482.119 15.63156 0.000 100.00 Likely temperature-limited before 2.50V cutoff. Did not cross 3.00V, so usable-above-cutoff equals the recorded total. Repaired 5 voltage samples using power/current because the raw voltage was outside a realistic cell range.
Linkdata 65P 52S CC Linkdata_65P_52S_CC_IT8516P_CC_52A_CONT_SENSEON_TEMP_2026-06-07_13-06-41.csv 52A CC 4.2143 3.3675 3.3675 3.3675 51.9323 200.483 182.909 3016.586 10.62495 3:29 209.106 24.56 80.01 55.45 3.5222 3016.586 10.62495 0.000 100.00 Likely temperature-limited before 2.50V cutoff. Did not cross 3.00V, so usable-above-cutoff equals the recorded total. Repaired 1 voltage samples using power/current because the raw voltage was outside a realistic cell range.
Linkdata 65P 100A CC Linkdata_65P_100A_CC_IT8516P_CC_100A_CONT_SENSEON_TEMP_2026-06-07_14-31-44.csv 100A CC 4.2097 2.9922 2.9922 2.9922 99.8966 357.608 329.730 1341.814 4.42896 0:49 48.558 26.54 64.66 38.12 3.3007 1341.658 4.42849 0.156 99.99 Ended above the intended 2.50V cutoff. Raw totals are not a full-depth comparison. Crossed 3.00V. Usable metrics were interpolated at the cutoff. Repaired 1 voltage samples using power/current because the raw voltage was outside a realistic cell range. Trimmed 5 trailing zero-voltage/near-zero-current sample(s) from the end of the file.

1. Voltage over Watt-hour

2. Power over Watt-hour

3. Temperature over Watt-hour

4. Current over Watt-hour

5. Capacity over Watt-hour

6. Voltage over Time

7. Power over Time

8. Temperature over Time

9. Usable Capacity Ranking above 3.00V

10. Raw Capacity Ranking

11. Peak Power Ranking

12. Maximum Temperature Ranking